C500
Tension Controller C500 is a device to control the running tension of sheet type processed material such as paper, cloth, fiber, film, rubber, and metal.
By changing the internal setting, it is suitable for a variety of machine configurations and can be used as a controller for unwind control, feed control, or rewind control.
Features of the C500
- Immediately deliverable
- Compact
- Door attachable
- Analog Output
- Compatible
- Supports control of unwinder, feeder, and rewinder using brake, clutch, electro-pneumatic converter/motor
- Enables connection of both LS series and LA series tension detector
- Supports dancer control in addition to control by tension pickup
- Enables flexible control using function to control line speed and roll diameter
- Enables operation linking to host systems such as sequencer
- Equipped with a variety of I/O
- Compatible with previous models C100 and C200
C500 Product Specification
Model | C500 |
---|---|
Power Supply | Voltage: 100 to 240 VAC Frequency: 50/60 Hz |
Input | ● Digital input 8 points 24 VDC, 5 mA, source input ● Analog input 6 points DC voltage input: common, with power supply for volume control -10 V to +10 V (10 MΩ input impedance) |
Output | ● Digital output 8 points 24 VDC, 100 mA, sink output ● Analog output Used for tension output/dancer output and control output · Analog voltage current switching output: 4 points Common -10 V to +10 V (10 mA max) -1 mA to +1 mA (±10 V max) switched · Analog voltage output: 4 points -10 V to +10 V (10 mA max) However, same signal source as power output and 4 to 20 mA output circuit |
Ambient environment | Ambient temperature : 0~50℃ |
Weight | 3.5Kg |
Dimensions (W x H x D) | 200 x 160 x 143 mm Mounting hole dimensions (W x H): 192 x 152 mm |
Connectible Equipment | ●Tension pickup · Both LA series and LS series tension pickup can be used · Supports both-end both side detection, both-end single side detection, independent detection method · Auto zero and auto scale functions · Allows analog output of total, left and right side separately ● Dancer potential · Retrieves signal from dancer position detection potentiometer · Auto adjuster function · Allows analog output of dancer position |
Power Consumption | Up to 200 VA |
Controlled devices | · Supports control of unwinder, feeder, rewinder using brake, clutch, electro-pneumatic converter · Supports control of feeder using motor · Supports dancer control in addition to tension control |
Communication Functions | · Used to communicate with the sequencer/PC · Communication by CC-LINK (requires installation of dedicated board) |