LSP
This detector is a coaxial type tension pick up using a strain gauge detector element.
Features of the LSP
- Immediately deliverable
- Explosion-proof specification available
- Compact
- Easy mounting
- Coaxial type
- Bearing-receiving type
- Small
- A coaxial type that requires no centering during assembly due to use of a spigot joint
- Two types: bearing-receiving type and fixed-axis type are available, both easy to maintain because the roller can be removed easily after assembly
- The detector has no adjuster and the same type are all compatible
- Highly accurate with a minimum deviation of zero points
- The mounting method and axial length of the roller are the same as the conventional LS-Z
- Roller eccentricity is hardly detectable with characteristics improved compared to conventional LS-Z series
- Displacement is small will little effect on the running equipment
- Three mounting adapters are available to enable fitting on both the inside and outside of the frame. Also, the position is reproducible even when the detector is removed or replaced because there is a spigot joint
- The fixed bearing can accommodate any kind of special bearing
- Wide range of applications as load cell as well tension detector
LSP Product Specification
Model | LSP00、LSP01、LSP05、LSP10、LSP01-Z (Explosion-proof specification)、 LSP05-Z (Explosion-proof specification)、LSP10-Z (Explosion-proof specification) |
---|---|
Input | Input resistance: 750 ± 10 Ω Input resistance (when connecting barrier box): 990 ± 12 Ω |
Output | Output resistance: 750 ± 5 Ω Output resistance (when connecting barrier box): 990 ± 7 Ω Rated output: Approx. 1.5 mV/V Rated output (when connecting barrier box): Approx. 1.1 mV/V |
Ambient environment | Operating temperature range: 0 to 40ºC Operating humidity range: 80% or less (non-condensing) |
Connectible Equipment | Connectable tension meter · TCS-550HG multi-channel tension meter (Model MSM) · T300 Connectable tension controller · C500 |
Non-linearity | 0.1%R.O |
Hysteresis | 0.1%R.O |
Load rating (RC) (per detector) |
LSP00:50N LSP01,LSP01-Z:100N LSP05,LSP05-Z:500N LSP10,LSP10-Z:1000N |
Reproducibility | 0.05%R.O |
Displacement | 0.08mmR.O |
Applied voltage | Detector alone: 10 V When barrier box is connected: 10 V (± 5 V) |
Maximum applied voltage | Detector alone: 15V When barrier box is connected: 12V(±6V) |
Zero-point temperature drift | ±0.06%R.O/10℃ |
Output temperature drift | ±0.06%LOAD/10℃ |
Allowable overload | 200%R.C |
Explosion-proof specification | The explosion-proof tension detector is the following type. Zener barrier box that must be connected · Barrier box: BX2000P * 2 barriers are required per detector. A structure with a total of four barriers attached inside the barrier box on the left and right side with one barrier box per tension meter. Note: Be sure to connect a barrier as to explosion-proof specification. |